Test Your Code Knowledge; Volume 1.10
TOPIC: BPV Section VIII Division 1 – Section VIII-1,UG-10, Recertified Material P-Number
————–
Question: May a material that was originally identified with a specification not permitted by Section VIII, Division 1, but was recertified by the vessel manufacturer to a permitted specification in accordance with UG-10(a)(2), use the same P-Number designation of the permitted specification?
Yes.